Send Message

Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes

Basic Information
Place of Origin: China
Brand Name: BOTO
Certification: MIL STD GB JIS JEDEC IEC ISO
Model Number: B-TCT-401
Minimum Order Quantity: 1PCS
Price: Discussible
Packaging Details: wooden case
Delivery Time: 15days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000PC/Month
Model: B-TCT-401 Internal Dim (CM): 30x30x30
External Dim(CM): 118x185x180 Sample Weight: 5KG
Low Temp Range: -10℃--60℃ HighTemp Rang: +80℃~200℃
Recovery Time: Within 3 Minutes Interior: SUS#304Stainless Steel Plate

Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes

 

Two-box temperature impact test box adopts upper and lower boxes (upper box high temperature, lower box low temperature). In the middle is blue extraction, which is the place where samples can be placed. Blue extraction switches up and down through the transmission device, and makes rapid conversion between high and low temperature two boxes, so as to realize temperature impact. The degree of tolerance under the continuous environment of extremely high temperature and extremely low temperature in a moment, so as to detect the chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest time.

product use:

The two-box temperature impact test box is suitable for the safety performance test of electronic components to provide reliability test, product screening test, and so on. At the same time, through this equipment test, the reliability of products and product quality control can be improved.

Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 0
Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 1
Meeting Standards:
GB/T2423.1.2-2001 GJB150.5 GB10592-89
 
characteristic:

◆ Beautiful appearance, reasonable structure, advanced technology, exquisite material selection, with simple and convenient operation performance and reliable equipment performance.

◆ The equipment is divided into high temperature box, low temperature box, test box three parts, adopt the unique heat breaking structure and heat storage cold storage effect, the test object to be measured is completely static, the application of cold and hot air circuit switch will be cold, hot temperature into the test area to achieve the purpose of cold and hot impact test.

Adopting the most advanced measuring device, the controller adopts the large color LCD man-machine touch dialogue LCD man-machine interface controller, simple operation, easy to learn, stable and reliable, Chinese and English display the complete system operation status, implementation and setting program curve.

With 96 test specifications independent setting, impact time 999 hours 59 minutes, cycle cycle 1~999 times can be set, can realize the automatic operation of the refrigerator, the maximum degree of automation, reduce the workload of the operator, can automatically start, stop running at any time;

The left side of the box has a test hole with a diameter of 50mm, which can be used for external power load wiring test parts.

◆ Can independently set the function of high temperature, low temperature and hot and cold impact three different conditions, and in the execution of hot and cold impact conditions, you can choose two or three trough type and cold, hot impact function, with high and low temperature testing machine.

◆ With full automatic, high precision system loop, any part action, fully P.L.C locking processing, all using P.I.D automatic calculation control, high precision temperature control.

◆ Advanced scientific air circulation circulation design, so that indoor temperature uniformity, avoid any dead corners; Complete safety protection device, avoid any potential safety risks, ensure the long-term reliability of the equipment

Automatic (manual) defrosting can be set the number of cycles and defrosting times.

◆ Detection and control of air outlet in return air taste detector, the switch time of damper mechanism is completed within 10 seconds, and the recovery time of cold and hot impact temperature is completed within 5 minutes.

◆ State display and curve display in operation, when abnormal conditions occur, the screen will automatically display the fault point and cause and provide troubleshooting method immediately, and when the input power is found unstable, with emergency shutdown device.

◆ The refrigeration system adopts the design of multiple high efficiency low temperature loop system. The refrigeration unit adopts the compressor originally imported from Europe and America, and adopts the green environmental protection (HFC) refrigerant R507, R23 with zero ozone coefficient.

◆ Super safety protection function: power overload protection, leakage protection, overload control loop, short circuit protection, compressor protection, grounding protection, over temperature protection, alarm sound prompt, etc.

 

Model:

(Model) B-TCT-401 B-TCT-402 B-TCT-403) B-TCT-501 B-TCT-502 B-TCT-503 B-TCT-601 B-TCT-602 B-TCT-603
 Internal Dim (CM) 30x30x30 40x40x40 50x50x50 30x30x30 40x40x40 50x50x50 30x30x30 40x40x40 50x50x50
External Dim(CM) 118x185x180 128x195x190 138x205x200 118x185x180 128x195x190 138x205x200 118x185x180 128x195x190 138x205x200
Sample Weight 5KG 10KG 20KG 5KG 10KG 20KG 5KG 10KG 20KG
Low Temp Range -10℃--60℃ -10℃~-70℃ -10℃--80℃
Test Temp Rang -40℃-150℃ -55℃~150℃ -65℃~150℃
HighTemp Rang
+80℃-200 ℃ lvarious specifications applicablel
Recovery time
Within 3 minutes
Interior SUS#304Stainless steel plate
Exterior Coating or SUS#304Stainless steel plate
Power Source AV:380V 50/60Hz
Power(KW) 13.5KW 15KW 19KW 13.5KW 15KW 19KW 15KW 19KW 22KW

 

 

Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 3
Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 4
 
Packing/Shipping:
 
Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 5
Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 6
Two-Box Temperature Impact Test Chamber, Meeting Standard GB/T2423.1.2-2001, Within 3 minutes 7
 
 

Contact Details
BOTO

Phone Number : +8613761261677

WhatsApp : +8613761261677