Send Message

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89

Basic Information
Place of Origin: China
Brand Name: BOTO
Certification: MIL STD GB JIS JEDEC IEC ISO
Model Number: B-T-225(A~E)
Minimum Order Quantity: 1PCS
Price: Discussible
Packaging Details: wooden case
Delivery Time: 15days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000PC/Month
Model: B-T-225(A~E) Internal: 60x75x50
External Dim: 90X177X130 Power Source: AV:220V/380V 50/60Hz
Heat-up Time: ±1.0℃/±3.0℃RH Temp&Humi.Deviation: -40℃-150℃
Relative Humidity: 20%~98%RH HighTemp Rang: +80℃~200℃
Interior: SUS#304Stainless Steel Plate Exterior: Coating Or SUS#304Stainless Steel Plate
High Light:

High Temperature Chamber GB10592-89

,

Programmable Lab Climatic Chamber

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89

 

Product Application

High low temperature test chamber is used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time, Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is high-temperature region, another is low-temperature region, the testing sample placed on the moving basket, using unique heat storage and cool storage, the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing; applied to test the material, including metal, plastic, rubber, electronics and other materials, it can be used as a basis for improvement of their products.

 

Programmable High Temperature Chambeis made in accordance with the light of new chemicals Pharmaceutical stability testing guidelines and humid test chamber technical conditions. The equipment may prepare a long and stable operating temperature and humidity environment by pharmaceutical scientific method for evaluation of drug failure require. It is used for companies to test drugs and calibration and stability tests for new drugs. Pharmaceutical stability chambers to meet the accelerated test, the test of long-term and high-humidity test, international organizations to identify new ICH stability testing conditions are also among the above range. Users can also press the unit Drug stability test chamber to arrange work requirements.

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 0

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 1

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 2

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 3

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 4

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 5

product feature:

The constant temperature and humidity test chamber is composed of two parts: temperature regulation (heating, cooling) and humidification. Through the rotating fan installed in the top of the box, the air is discharged into the box to achieve gas circulation and balance the temperature and humidity inside the box. The data collected by the built-in temperature and humidity sensor of the box is transmitted to the temperature and humidity controller (micro information processor) for editing and processing, and the temperature and humidity control instructions are issued. Through the air heating unit, condensing pipe and the tank heating and evaporation unit.

 

Constant temperature and humidity box temperature regulation is through the box built-in temperature sensor, data collection, temperature controller (micro information processor) adjustment, connected to the air heating unit to increase the temperature or adjust the refrigeration solenoid valve to reduce the temperature in the box, in order to achieve the required temperature control. Constant temperature and humidity box humidity regulation is through the body set humidity sensor, data collection, humidity controller (micro information processor) adjustment, connected to the tank heating element, through the evaporation of water in the tank to increase the humidity in the box or adjust the refrigeration solenoid valve to achieve dehumidification, in order to control the required humidity.

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 6

operation:

Through three interconnected systems: refrigerant circulation system, air circulation system, electrical automatic control system.

1. Refrigerant circulation system of constant temperature and humidity test chamber: The liquid refrigerant in the evaporator absorbs the heat of the air (the air is cooled and dehumidified) and begins to evaporate. Finally, a certain temperature difference is formed between the refrigerant and the air. The liquid refrigerant also completely evaporates into the gas phase, and is then inhaled and compressed by the compressor (pressure and temperature increase). After being throttled through the expansion valve (or capillary), low temperature and low pressure refrigerant enters the evaporator to complete the refrigerant circulation process.

2. Air ring system of constant temperature and humidity test chamber: the fan is responsible for inhaling the air from the return air outlet, and the air is sent to the space required by the user through the air supply outlet after passing through the evaporator (cooling and dehumidification), humidifier and electric heater (heating). The sent air mixes with the air in the space and returns to the return air outlet.

product description:

 

PD-SO

model B-RUL-45 B-RUL--60 B-RUL-80 B-RUL-100
design dimension 45x45x45 60x60x60 80x80x80 100x100x100
carton size 103x123x77 118x138x92 138x158x112 158x178x132
  RT+10℃-200℃(1300°℃)
economy

model

 

DHG-9030A
101A-0S
DHG-9070A
101A-1S
DHG-9140A
101A-2S
DHG-9240A
101A-3S
DHG-9420A
101A-4S
DHG-9620A
volume 30L 70L 136L 220L 420L 620L
 Interior dimension 350*350*350 450*350*450 550*450*550 600*500*750 640*585*1355 840*600*1355
mmW*D*H carton size 480*470*685 580*470*785 680*590*885 730*640*1085 780*750*1880 980*800*1880
temperature fluctuation ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
temperature resolution 0.1℃ 0.1℃ 0.1℃ 0.1℃ 0.1℃ 0.1℃
temperature control range RT+10-250℃ RT+10-250℃ RT+10-250℃ RT+10-250℃ RT+10-200℃ RT+10-200℃
mains input 220V 50HZ 220V 50HZ 220V 50HZ 220V 50HZ 220V 50HZ 220V 50HZ
input powe 650W 1500W 2000W 2400W 4000W 4800W
volume 30L 70L 136L 220L 420L 620L

 

Our Company:

 

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 7

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 8

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 9

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 10

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 11

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 12

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 13

Climatic Chamber Lab Machine GB/T2423.2 Programmable High Temperature Chamber GB10592-89 14

FAQ:

Q: Are your company a trading one or a factory?
A: We are a factory over18-year experience.

Q: After an order is placed, when to deliver?
A: Generally about 25days. If we have inventory, we can arrange to ship within 3-5 days. Please be aware that our production lead times depend on specific items and item quantities.

Q: What about the product' services and quality?
A: We have Pre-service, middle-service and after-sale service.
Can provide video training to show you how to install & operate. We can also arrange engineer to train the operation of equipment to customer's company when you need. Core components almostly are from the import.

Contact Details
BOTO

Phone Number : +8613761261677

WhatsApp : +8613761261677